ماژول تایمر قابل تنظیم 12 تا 24 ولت با خروجی CMOS
DC 5V-36V Timer Module Trigger Cycle Delay Timer Switch Turn On/Off Relay Module with LED Display
The multi-function timer module with MOSFET output is a very practical module that has attractive features designed for it.
This programmable module has the ability to be stimulated by an external signal and its output can be activated in several modes
The delay time and working modes can be adjusted by the keys on the board.
The time can be set between 0.1 seconds and 999 minutes.
Also, the time setting resolution can be set in three modes: 0.1 second, 1 second and 1 minute.
The input voltage of the module is between 5 and 36 volts DC.
The external excitation signal can also be between 3 and 24 volts.
Also, the module is protected against wrong connection of voltage polarity
Two switching MOSFETs are placed on this product, which can control loads with a maximum current of 15 amps.
Main Features
Digital tube display
Support high level trigger
Emergency stop function
Sleep mode,Wake up with any button
Automatically save parameters
Dual MOS control support more than 15A 400W
Support reverse connection protection
Continuously adjustable from 0.01 seconds to 999 minutes
Optocoupler isolation to enhance anti-interference ability
Size: 6.0×3.4×1.2cm
Application
Motor
Robot
Smart home
Industrial control
Automatic irrigation
Indoor ventilation
Illumination
Alarm system
Instruction
Operating Mode
P1: trigger signal, the relay is on “OP” time, and then disconnect; in the “OP” time, as follows:
P1.1: signal is triggered again, invalid
P1.2: signal is triggered again, the clocking is reset
P1.3: Signal is trigger again reset, relay off, and stop the clocking;
P-2: trigger signal, the relay off “CL” of time, the relay on “OP” time, and then disconnect relay after clocking;
P3.1: trigger signal, the relay is turned on after the “OP” time, the relay off “CL” time, then the operation cycles; if trigger signal again during the cycle, the relay off, stop clocking; the number of cycles times ( “LOP “) can be set.
P3.2: without triggering signal after power on, the relay is on “OP” time, the relay off “CL” time, then the operation cycles; the number of cycles times ( “LOP “) can be set.
P-4: signal holding function. If there is trigger signal, clocking is reset, the relay remains on; when the signal disappears, after clocking “OP” time, the relay is off; if another signal is triggered during clocking, clocking will be reset.
How to Set Clocking Range
After setting the parameter value at mode selection, press “STOP” button to set the clocking range;
XXX. The last decimal point lights up, range: 1 second to 999 seconds.
XX. X The second last decimal point lights up, range: 0.1 seconds to 99.9 seconds
X. X. X. all 3 decimal points light up, range: 1 minute to 999 minutes.
For example, if you want to set “OP” as 3.2 seconds, light up the second last decimal point, and set digit display as 03.2.
Parameter Description
“OP” – on time, “CL” – off time, “LOP” – number of cycle times (1-999 times, “—” represents infinite loop).
These parameters are independent of each other, but are shared by each mode. For example, in P1.1 mode, set the on-time “OP” is 5 seconds, if you switch to P1.2 mode, its “OP” will also be 5 seconds.
In the main interface (display 000), press “SET” button will display “OP” ( “CL”, “LOP”) and the corresponding time XXX;
If the mode (such as the mode P1.1, P1.2, P1.3) only has “OP” time, press the “SET” key to display only the “OP” and the corresponding time;
Some models (such as the mode P3.1, P3.2) have parameters “OP”, “CL”, “LOP”, press “SET” button will display “OP” and the corresponding time, “CL” and the corresponding time, “LOP” and the corresponding number of times;
After setting mode, in the main interface press “SET” key to see information about the parameters of the current mode, very convenient.
How to Set Parameters
1. First, read the instructions to determine the required operating mode.
2. The module is powered up, the display at the current work mode (P1.1 default mode), then enter the main interface; press and hold “SET” button for 2 seconds to enter mode selection interface; then press “UP”, “DOWN” button to select the mode (P1.1 ~ P-4).
3. Select the mode (such as P3.2), then press the “SET” button, the parameter to be set flashes ( “OP” on-time, “CL” off time, “LOP” cycles ( “—” represents infinite loop)), press(or press and hold) “UP”, “DOWN” button to adjust the parameter value; then press the “STOP” key to set the decimal point position to select the clocking range (0.1 seconds to 999 minutes); press the “SET” button to set the next parameters of the current mode, method is same as above.
4. After the parameters are set, press and hold “SET” button for 2 seconds, then the current mode will flash once, and then return to the main interface, which means the parameters are successfully set.
The main interface: If the relay is not in work state, it display “000” with no decimal point), if it is in work state, it has decimal point.
Mode selection screen: Press and hold the “SET” button to enter; after setting, press and hold the “SET” button to exit back to the main interface.
Relays Enable Mode
1. ON: Relay allows conduction in the “OP” on-time;
2. OFF: Relay prohibits conduction and is always closed;
In the main interface, press the “STOP” button to switch between ON and OFF, the current state will flash, and then return to the main interface. (This feature is an emergency stop function, press on button to disconnect relay)
Sleep Mode
1. “C-P” Sleep mode: five minutes without any operation, the digital display automatically turns off, the program running as usual;
2. “O-d” Normal mode: digital display turns on always;
Press hand hold the “STOP” button for two seconds to switch “C-P” and “O-d” state, the current state flashes and then return to the main interface.
Note
1. The module is an active output, the output voltage equal to the input voltage.
2.’DC + ‘and’ load + ‘ are internally shorted(connected), but’ DC- ‘and’ load – ‘ cannot be shorted, otherwise the load cannot be controlled on and off, which is equivalent to load being powered on always.
دیدگاهها
هیچ دیدگاهی برای این محصول نوشته نشده است.