XY-TR01 Thermostat Temperature Humidity Sensor Thermometer Hygrometer Controller Module with LED Digital Display Dual Output DC6-30V
Characteristics
Temperature range: -20 ° C ~ 60 ° C
Humidity range: 00% ~ 100% RH
Control accuracy: 0.1 ° C 0.1% RHE
Output capacity: up to 10A
Size: 6×5.7cm / 2.36×2.24inch
A function
Product characteristics are two main types of classification: temperature and humidity functions.
The temperature functions are as follows
Automatic identification of the working mode:
The system automatically according to the start / stop temperature, identify the working mode;
Start temperature> stop temperature, cooling mode “C”.
Start temperature <stop temperature, heating mode “H”.
Cooling mode
When the temperature ≥Starting temperature, relay conduction, red light on, the refrigeration equipment starts to work;
When the temperature is lower than the shutdown temperature, the relay is disconnected and the red light is off, the refrigeration equipment stops working.
Heating mode
When the temperature is lower than the initial temperature, the conduction of the relay, the red light on, the heaters start to work;
When the temperature ≥ Stop temperature, relay disconnection, red light off, the heating equipment stops to work;
OFE temperature correction function (-10.0 ~ 10):
The system has been operating for a long time and can be biased, by this function correction, the actual temperature = measurement temperature + calibration value.
How to set the start / stop temperature
1. In the running interface, long press “TM +” key for more than 3 seconds, in the start temperature setting interface, can be changed by TM + TM key, for be modified, waiting for the automatic 6 s output and recording.
2. In the running interface, long press “TM-” key for more than 3 seconds, in the shutdown temperature setting interface, can be changed by TM + TM key, to be changed after settings, waiting for 6s automatic output and recording.
The humidity function is as follows
Automatic identification of the working mode
The system automatically according to the start / stop humidity, identify the working mode;
Start humidity> stop humidity, dehumidification mode ‘D’.
Start humidity <stop humidity, humidification mode ‘E’.
Dehumidification mode
When humidity ≥ Starting humidity, relay conduction, green light on, dehumidification equipment starts to operate;
When humidity ≤ Stophumidity, the relay disconnects, the green light is off, the dehumidification equipment stops to work;
Humidification mode
When humidity start to work, relay conduction, green light on, humidification equipment start to work;
When the humidity ≥Stophumidity, the relay disconnects, the green light is off, the humidification equipment stops working;
RH humidification correction function (-10.0 ~ 10%):
The system operates for a long time and can be biased, by this function correction, the actual humidity rate = humidity measurement + calibration value;
How to set the start / stop humidity
1.In the running interface, long press the ‘RH +’ key for more than 3 seconds, in the humidity settings start interface, can be changed by the RH + RH- key, to be modified, while waiting for the automatic 6 s exit and recording;
2.In the operation interface, long press the “ RH- ” key more than 3 seconds, in the humidity settings shutdown interface, can be changed by the RH + RH- key, to be modified after the parameters, waiting for the automatic 6 s exit and recording
Description of the running interface
The working mode indicates that the current mode (“H / C”, “E / d”) will be synchronized ahead of temperature / humidity, once the temperature / humidity is set and temperature / shutdown is set. humidity finished.
Any relay conduction, the upper left corner of the interface displays “out”, if the temperature relay conduction, the flashing display temperature “H / C” operating mode to display reminders; if the humidity relay is in conduction, the humidity operating mode “E / d” flashes, as a reminder.
Other characteristics
Remote read / set parameter
By means of the UART, define the correction parameters for the starting temperature / humidity, stop temperature / humidity, temperature / humidity;
Temperature / Humidity Real-time reports
If the temperature / humidity reporting function is enabled, the product will detect the temperature / humidity and relay status at an interval of 1 second, then transmit the UART to the terminal to facilitate data collection.
Relay activation (default)
If the relay is deactivated, it remains disconnected.
How to modify the temperature / humidity correction value
1.In the operation interface, double click ‘TM +’ key to enter the correction of the defined interface, the display correction down type, the display up specific values; (OFE: temperature correction value RH: humidity correction value)
At this moment, by a short press on the ‘TM-‘ key, toggle to modify the parameters, by using the RH + RH key, modify the specific value of the support long press the short key.
3.When the parameters have been changed, double click the ‘TM +’ key, exit the positive correction adjustment interface and save the data.
Package Included
1 x XY-TR01 Thermometer Hygrometer Controller Module
1 x sensor cable
فیش مادگی منبع تغذیه مشکی
۱۱,۹۰۰ تومان
نوک هویه ۱۰۰ وات سومو مدل SM1100T
۲۵۵,۰۰۰ تومان
ماژول نمایشگر و کنترل دما و رطوبت دیجیتال مدل XY-TR01
۶۴۵,۰۰۰ تومان
موجود در انبار
24
نفر در حال مشاهده این محصول هستند!
دسته: دما و رطوبت, ماژول ها
توضیحات
نظرات (0)
اولین نفری باشید که دیدگاهی را ارسال می کنید برای “ماژول نمایشگر و کنترل دما و رطوبت دیجیتال مدل XY-TR01”
محصولات مشابه
ماژول کاهنده LM2596 حداکثر جریان خروجی 3 آمپر
۳۷,۰۰۰ تومان
ماژول آمپلی فایر 5W کلاس D با تراشه PAM8406
۳۵,۰۰۰ تومان
ماژول آمپلی فایر 2x3W کلاس D با تراشه PAM8403
ماژول آمپلی فایر استریو 3 وات PAM8403 همراه با ولوم متغیر
ماژول کی پد 4 در 4 لمسی TTP229
۷۹,۰۰۰ تومان
تگ RFID سر کلیدی فرکانس 13.56MHz
۱۳,۵۰۰ تومان
ماژول وای فای و بلوتوث ESP32-CAM
مبدل USB به سریال RS485
۴۹,۰۰۰ تومان
دیدگاهها
هیچ دیدگاهی برای این محصول نوشته نشده است.